PRINCIPLE
Still lightweight and portable, the Tixel 2 is able to utilize both the standard hand piece and a peri-orbital hand piece on the device; allowing the user to alternate between the two as and when needed during a treatment.
TMA TECHNOLOGY
Tixel is powered by TMA (Thermo-Mechanical Action), a non-laser fractional treatment technology that can transfer thermal energy to the skin very quickly and safely. The energy is emitted through a matrix of tiny pyramid-shaped pins made of bio compatible materials covering a treatment area of 1cm². The pins are heated to a temperature of 400°C, similar to the temperature generated by a CO₂ laser beam when it interacts with the skin.
During treatment, the pins are introduced at a precisely controlled speed to the surface of the skin, after which the thermal energy stored in the pins is rapidly transferred to the skin upon brief contact lasting only a few milliseconds. The ensuant evaporation of water from the skin occurs instantaneously, resulting in the formation of tiny micro pores in the treatment zone. The tiny pyramids hold a limited amount of energy and evaporate the upper layers of the skin in a controlled manner without causing burns or charring in the tissue, a side effect often seen with other energy sources such as laser.

Tissue Evaporation by the tip upon brief contact with the skin
FEATURES
What is Tixel?
Tixel is a novel thermal fraction skin rejuvenation system powered by Novoxel’s patented technology.
Why Tixel?
- Tixel is similar in effectiveness to fractional lasers.
- It is a cost effective, sterile, fractional device for controlled evaporation of tissue.
- Compared to laser, Tixel treatment is safe with:
- Less charring and crusting
- Less pain without anesthesia or cooling
- Less downtime and post care
- No irradiation, just pure natural heat

TIXEL VERSATILITY
Tixel can perform either ablative or non-ablative treatments. The extent of thermal damage generated is closely related to the choice of the tip and to pulse duration. By adjusting treatment parameters, the physician can control the extent of ablation, the thermal effect, downtime and duration of healing.

SPECIFICATIONS
Energy Type
Natural heat, w/o radiation or radio waves
Tip Material
Titanium Surface
Tip Coverage Area
1 cm2
System Weight
5 kg
Handpiece Weight
330 grams
System Dimensions
L 48 x W 41 x H 48 (cm)
Operating Voltage
100-240 VAC 10% ± 2.5A 50/60Hz
Operating Power
up to 300 W
Working Temperature
400° C (-15°C/+5°C)
Pulse Duration
*Double pulse is enabled between 8 to 12 ms
5-18 milliseconds (±1 millisecond)
(possible durations: 5,6,8,10,12,14,16,18)
Pulse Protrusion
100-1000 µm, intervals of 100 µm
Micropore Dimensions
from 100 x 100 µm to 300 x 300 µm (W x D)
DOWNLOAD
Download the Tixel brochure which contains more information:
- Product Information
- Use Cases
- Technical Specifications
- & Examples